1303
MASONRY MORTAR 3MPa
Practical for standard strength masonry
Masonry mortar
- Cement and lime binder: easy to work with.
- Suitable for machine working: allows efficient working.
Area of application
- Outdoors: wall
- Indoor: wall
Processing method
- For hand and machine processing
- Masonry mortar for the construction of new and old residential buildings, public buildings, industrial buildings (ceramic masonry, brick, stone, concrete block, gas concrete, etc.). According to the static designs, it can be used for the construction of load-bearing walls, pillars, chimneys and partitions, depending on the different loads.
Price list
Code
Packaging
Code
Packaging
25 kg
Processing details
Learn more about technical details for processing this product.
Substrate requirement
The substrate and the masonry units must be prepared in accordance with the instructions of the architect and the masonry unit manufacturer.
Substrate preparation
When applying MM 3 masonry mortar, the substrate and the masonry units must be prepared in accordance with the instructions of the architect and the masonry unit manufacturer.
Preparation of the mixture
MM 3 masonry mortar is mixed with water at the construction site without lumps. Mixing can be done in a concrete mixer, by a horizontal mixer (e.g. PFT HM24), by hand mixer (using a suitable mixing arm) or by hand.
Consumption: approx. 1,8 kg/1 litre mortar. The exact amount of required material can be determined by test application.
Water demand
Quantity | Liters (recommended) |
---|---|
25 kg | 4 |
40 kg | 6 |
Mixing
Processing instructions
Apply by hand, using traditional masonry tools and following the masonry technology. The temperature of the substrate, material and air must be between +5°C and +25°C. Always follow the technical specifications of the manufacturer of the masonry unit when preparing the masonry. Unless the manufacturer of the masonry unit specifies otherwise, fill both horizontal and vertical grouts.
Application thickness
Minimum layer thickness | 10 mm |
---|---|
Maximum layer thickness | 15 mm |
Working time (potlife)
180 min
Treatment after application
The mortar must not be exposed to frost during the setting period!
Tool and cleaning instructions
Wash off tools with water immediately after finishing work. Clean dried residues mechanically.
Technical parameters
Main binder | Grey cement |
Made of material | Cement and lime binders, mineral fillers and property improving additives. |
Flammability class | A1 |
Max. grain size | 2mm |
Compressive strength 28 days in N/mm² | 3 N/mm² |
Water absorption | W1 |
Thermal conductivity λ in W/(m.K) | 0.79 |
Dry bulk density in Kg/m³ to | 1900 |