2002
PRE-SPRINKLER

For secure adhesion to any masonry

Optimum substrate preparation against stress and shrinkage cracks.

  • Improves mechanical adhesion: Creates a rough, non-slip surface and better grip between masonry and base plaster.
  • Balances the absorption behavior: Highly absorbent substrates dry out the plaster too quickly. The pre-sprinkler acts as a buffer and ensures low-stress setting behavior of the plaster.
  • Prevents shrinkage cracks: The spray coating reduces the risk of such premature drying cracks.

Area of application

  • Outdoors: wall
  • Indoor: wall

Processing method

  • For hand and machine processing
  • Pre-sprinkler for external and internal walls in new and old residential buildings, industrial buildings before using base plasters. For masonry made of ceramic, brick, stone, concrete, aerated concrete, etc., and for wood wool boards to level the absorbency of the surface and increase the adhesion of the plaster.

Processing details

Learn more about technical details for processing this product.

Substrate requirement

The substrate must meet relevant standards and be sound, stable, and free from loose particles, dust, dirt, oil, mould release residues, and efflorescence.

Substrate preparation

Before starting work, cover all surfaces that need protection.
Any wall defects must be repaired at least three days in advance. Remove all loose plaster and fill large cracks and pipe grooves using base plaster.
If necessary, moisten the surface a few hours prior to application using a pre-sprinkler.

Preparation of the mixture

Pour 25KG of CEMIX 2002 CEMENT PRE-SPRINKLER into 5,6 L clean water (approximately 0,23 l/kg). Mix for 5 minutes with a slow-speed paddle mixer to a homogeneous mixture without lumps. Leave to rest for 3 minutes. Then mix again briefly.

Water demand

Quantity Liters (recommended)
25 kg 5,6

Processing instructions

The pre-sprinkler is applied with traditional masonry pan.

Application thickness

CEMIX_blue_techdata_cca_5mm
Recommended layer thickness 5 mm

Consumption

CEMIX_blue_techdata_trowel_cca_6kg/m2
Material consumption min.
4.8
Material consumption max.
-
Material consumption in measuring unit
kg/m²

Working time (potlife)

CEMIX_blue_handling_trowel_120min

120 min

Treatment after application

The pre-sprinkler must not be exposed to frost during the curing period!

Tool and cleaning instructions

Wash off tools with water immediately after finishing work. Clean dried residues mechanically.

Technical parameters

Main binder Grey cement
Flammability class A1
Max. grain size 2mm
Compressive strength 28 days in N/mm² 15 N/mm²
Flexural strength 28 days in N/mm² 5 N/mm²
Thermal conductivity λ in W/(m.K) 1.17
Dry bulk density in Kg/m³ to 2000

Files

Technical datasheet
Simple Transactional Email